¡ö CHARACTERISTICS
Closed Center - Non Reaction and Load Sensing Outlet, PVF* Priority Valve Connectiom: modulary mounting.
Comparison :
102S-5-50 =HKUS50/5
102S-5-80 =HKUS80/5
102S-5-100 =HKUS100/5
102S-5-125 =HKUS125/5
102S-5-160 =HKUS160/5
102S-5-200 =HKUS200/5
102S-5-250 =HKUS250/5
102S-5-315 =HKUS315/5
102S-5-400 =HKUS400/5
¡ö TECHNICAL DATA
TYPE
|
Displacement
|
Max. input speed
|
Max.input
|
Max.Cont.Back
|
Normal Input
|
Length
|
(ml/r)
|
(rpm)
|
Pressure (Mpa)
|
Pressure (Mpa)
|
Torque (N.m)
|
(mm)
|
102S-5-50
|
50
|
100
|
16
|
2.5
|
<5
|
130
|
102S-5-63
|
63
|
100
|
16
|
2.5
|
<5
|
132
|
102S-5-80
|
80
|
100
|
16
|
2.5
|
<5
|
134
|
102S-5-100
|
100
|
100
|
16
|
2.5
|
<5
|
137
|
102S-5-125
|
125
|
100
|
16
|
2.5
|
<5
|
140
|
102S-5-160
|
160
|
100
|
16
|
2.5
|
<5
|
145
|
102S-5-200
|
200
|
100
|
16
|
2.5
|
<5
|
150
|
102S-5-250
|
250
|
100
|
16
|
2.5
|
<5
|
156
|
102S-5-280
|
280
|
75
|
16
|
2.5
|
<5
|
161
|
102S-5-315
|
315
|
75
|
16
|
2.5
|
<5
|
166
|
102S-5-400
|
400
|
75
|
16
|
2.5
|
<5
|
176
|
|